1.
Curr Med Sci ; 41(6): 1151-1157, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34907474

RESUMO

OBJECTIVE: This paper proposes a new photoacoustic computed tomography (PACT) imaging system employing dual ultrasonic transducers with different frequencies. When imaging complex biological tissues, photoacoustic (PA) signals with multiple frequencies are produced simultaneously; however, due to the limited bandwidth of a single-frequency transducer, the received PA signals with specific frequencies may be missing, leading to a low imaging quality. METHODS: In contrast to our previous work, the proposed system has a compact volume as well as specific selection of the detection center frequency of the transducer, which can provide a comprehensive range for the detection of PA signals. In this study, a series of numerical simulation and phantom experiments were performed to validate the efficacy of the developed PACT system. RESULTS: The images generated by our system combined the advantages of both high resolution and ideal brightness/contrast. CONCLUSION: The interchangeability of transducers with different frequencies provides potential for clinical deployment under the circumstance where a single frequency transducer cannot perform well.


Assuntos
Aumento da Imagem/instrumentação , Técnicas Fotoacústicas/instrumentação , Tomografia/instrumentação , Transdutores , Desenho de Equipamento , Humanos , Imagens de Fantasmas
2.
Sci Rep ; 11(1): 19273, 2021 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-34588556

RESUMO

Chest electrical impedance tomography (EIT) is a promising application which is used to monitor the ventilation and perfusion of the lung at the bedside dynamically. The aim of the study was to introduce the first Chinese made chest EIT device for ICU application (Pulmo EIT-100). The system design of the hardware and software was briefly introduced. The performance of the system was compared to PulmoVista 500 (Dräger Medical) in healthy volunteers. The EIT system Pulmo EIT-100 consists of impedance measurement module, power supply module, PC all-in-one machine, medical cart and accessories. The performance of the system current source and voltage measurement unit was tested. A total of 50 healthy lung volunteers were prospectively examined. Subjects were asked to perform repetitive slow vital capacity (SVC) maneuvers with a spirometer. EIT measurements were performed in the following sequence during each SVC with: (1) Pulmo EIT-100, (2) PulmonVista500, (3) Pulmo EIT-100 and (4) PulmonVista500. Linearity and regional ventilation distribution of the reconstructed images from two devices were compared. The output frequency stability of the current source was 2 ppm. The amplitude error within one hour was less than 0.32‰. The output impedance of the current source was about 50kΩ. The signal-to-noise ratio of each measurement channel was ≥ 60 dB. For fixed resistance measurements, the measured values drifted about 0.08% within one hour. For human subjects, the correlations between the spirometry volume and EIT impedance from two devices were both 0.99 ± 0.01. No statistical significances were found in the parameters investigated. The repeatability (variability) of measures from the same device was comparable. Our EIT device delivers reliable data and might be used for patient measurement in a clinical setting.


Assuntos
Unidades de Terapia Intensiva , Monitorização Fisiológica/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Tomografia/instrumentação , Adulto , China , Impedância Elétrica , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Pulmão/fisiologia , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Estudos Prospectivos , Ventilação Pulmonar/fisiologia , Reprodutibilidade dos Testes , Software , Tomografia/métodos
3.
J Microsc ; 284(1): 25-44, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34110027

RESUMO

We present a software-assisted workflow for the alignment and matching of filamentous structures across a three-dimensional (3D) stack of serial images. This is achieved by combining automatic methods, visual validation, and interactive correction. After the computation of an initial automatic matching, the user can continuously improve the result by interactively correcting landmarks or matches of filaments. Supported by a visual quality assessment of regions that have been already inspected, this allows a trade-off between quality and manual labour. The software tool was developed in an interdisciplinary collaboration between computer scientists and cell biologists to investigate cell division by quantitative 3D analysis of microtubules (MTs) in both mitotic and meiotic spindles. For this, each spindle is cut into a series of semi-thick physical sections, of which electron tomograms are acquired. The serial tomograms are then stitched and non-rigidly aligned to allow tracing and connecting of MTs across tomogram boundaries. In practice, automatic stitching alone provides only an incomplete solution, because large physical distortions and a low signal-to-noise ratio often cause experimental difficulties. To derive 3D models of spindles despite dealing with imperfect data related to sample preparation and subsequent data collection, semi-automatic validation and correction is required to remove stitching mistakes. However, due to the large number of MTs in spindles (up to 30k) and their resulting dense spatial arrangement, a naive inspection of each MT is too time-consuming. Furthermore, an interactive visualisation of the full image stack is hampered by the size of the data (up to 100 GB). Here, we present a specialised, interactive, semi-automatic solution that considers all requirements for large-scale stitching of filamentous structures in serial-section image stacks. To the best of our knowledge, it is the only currently available tool which is able to process data of the type and size presented here. The key to our solution is a careful design of the visualisation and interaction tools for each processing step to guarantee real-time response, and an optimised workflow that efficiently guides the user through datasets. The final solution presented here is the result of an iterative process with tight feedback loops between the involved computer scientists and cell biologists. LAY DESCRIPTION: Electron tomography of biological samples is used for a three-dimensional (3D) reconstruction of filamentous structures, such as microtubules (MTs) in mitotic and meiotic spindles. Large-scale electron tomography can be applied to increase the reconstructed volume for the visualisation of full spindles. For this, each spindle is cut into a series of semi-thick physical sections, from which electron tomograms are acquired. The serial tomograms are then stitched and non-rigidly aligned to allow tracing and connecting of MTs across tomogram boundaries. Previously, we presented fully automatic approaches for this 3D reconstruction pipeline. However, large volumes often suffer from imperfections (ie physical distortions) caused by the image acquisition process, making it difficult to apply fully automatic approaches for matching and stitching of numerous tomograms. Therefore, we developed an interactive, semi-automatic solution that considers all requirements for large-scale stitching of microtubules in image stacks of consecutive sections. We achieved this by combining automatic methods, visual validation and interactive error correction, thus allowing the user to continuously improve the result by interactively correcting landmarks or matches of filaments. We present large-scale reconstructions of spindles in which the automatic workflow failed and where different steps of manual corrections were needed. Our approach is also applicable to other biological samples showing 3D distributions of MTs in a number of different cellular contexts.


Assuntos
Tomografia com Microscopia Eletrônica , Fuso Acromático , Tomografia/instrumentação , Técnicas Histológicas , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional , Microtúbulos , Software
4.
Appl Opt ; 60(10): B81-B87, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33798139

RESUMO

Data acquisition and processing is a critical issue for high-speed applications, especially in three-dimensional live cell imaging and analysis. This paper focuses on sparse-data sample rotation tomographic reconstruction and analysis with several noise-reduction techniques. For the sample rotation experiments, a live Candida rugosa sample is used and controlled by holographic optical tweezers, and the transmitted complex wavefronts of the sample are recorded with digital holographic microscopy. Three different cases of sample rotation tomography were reconstructed for dense angle with a step rotation at every 2°, and for sparse angles with step rotation at every 5° and 10°. The three cases of tomographic reconstruction performance are analyzed with consideration for data processing using four noise-reduction techniques. The experimental results demonstrate potential capability in retaining the tomographic image quality, even at the sparse angle reconstructions, with the help of noise-reduction techniques.


Assuntos
Holografia/instrumentação , Holografia/métodos , Tomografia/instrumentação , Tomografia/métodos , Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Pinças Ópticas , Rotação , Saccharomycetales , Razão Sinal-Ruído
5.
Br J Ophthalmol ; 105(1): 22-26, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32217537

RESUMO

PURPOSE: To assess the repeatability and reliability of the most important tomographic parameters for characterising keratoconus measured with a Pentacam HR (high resolution). METHODS: Overall, 230 eyes in 158 patients with keratoconus were analysed. We performed five consecutive corneal tomography examinations for each eye with a Pentacam HR in patients with keratoconus. Study eyes were classified into three groups depending on the maximum posterior elevation (max_BFS_post): grade 1 for cases of keratoconus with a max_BFS_post of 40 µm; grade 2 for those with a max_BFS_post of between 41 and 75 µm and grade 3 for those with a max_BFS_post of over 75 µm. We calculated the intraclass correlation coefficients (ICCs) and repeatability limits of parameters from tomography and aberrometry. RESULTS: All the parameters were found to have excellent ICCs (0.9). The repeatability limits for the key parameters were higher than 0.5D for the power parameters, 20° for the axis of corneal astigmatism and 10 µm for the thinnest corneal thickness. Further, we obtained repeatability limits of above 0.1 µm for the aberrometry values and overall greater than 15° for the coma axis. All the values increase with the severity of keratoconus, except for that of the coma axis which falls with keratoconus grade. CONCLUSIONS: The reliability indicated by ICCs supports the view that the Pentacam HR is useful for the diagnosis of keratoconus. The repeatability limits suggest that new criteria should be established for monitoring progression taking into account the real measurements that can be made using this system.


Assuntos
Diagnóstico por Imagem/métodos , Ceratocone/diagnóstico por imagem , Aberrometria , Adulto , Paquimetria Corneana , Topografia da Córnea , Feminino , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia/instrumentação , Acuidade Visual , Adulto Jovem
6.
PLoS One ; 15(12): e0243370, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33270786

RESUMO

PURPOSE: To evaluate the correlation between corneal thickness (CT) measurements obtained with two Scheimpflug devices, Pentacam HR and Precisio, and to elaborate, if necessary, a regression formula which could make these results comparable. DESIGN: Retrospective, Comparative, Observational study. SETTING: Department of Medicine, Surgery and Dentistry, "Scuola Medica Salernitana" University of Salerno, Italy. METHODS: One hundred twenty four healthy eyes of 124 volunteers (65 males; range: 20-32 years; mean age of 24.8 ± 1.7) were included in this study. CT was measured using Pentacam HR and Precisio in three different points: the pupil center (PC), the corneal apex (CA) and the thinnest point (TP). RESULTS: CT obtained with both devices at the PC, at the CA and at the TP showed a good correlation (r = 0.97, r = 0.97, r = 0.97, respectively), but Pentacam HR measurements were significantly thicker than those provided by Precisio (p < 0.01). The differences between Pentacam HR and Precisio were 21.9 ± 8.8 µm at the PC, 21.9 ± 8.9 µm at the CA, 19.1 ± 9.0 µm at the TP. The calculated regression formulas were: y = 0.9558x + 2.3196 for the PC, y = 0.9519x + 4.5626 for the CA, y = 0.9364x + 15.436 for the TP, where x is the CT measured with Pentacam HR and y is the Precisio measurement. CONCLUSIONS: The findings provided by this study highlight that Precisio measures thinner corneas compared to Pentacam HR. The identified regression formulas could be utilized to make interchangeable the results obtained with these two devices.


Assuntos
Córnea/diagnóstico por imagem , Paquimetria Corneana/instrumentação , Tomografia/instrumentação , Adulto , Córnea/anatomia & histologia , Feminino , Voluntários Saudáveis , Humanos , Itália , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
7.
Phys Med Biol ; 65(21): 215024, 2020 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-33151907

RESUMO

Magneto-acousto-electrical tomography (MAET) is an imaging method coupled with sound field and magnetic field. The aim of this study is to present some novel experimental results of the mouse liver for the magneto-acousto-electrical tomography measured by two electrodes. The magnetic field in the space of 60 mm3 is about 300 mT which generate by two permanent magnets. A plane transducer with 2.25 MHz center frequency is utilized to generate acoustic waves inside the object. The signal is detected by two similar 1 mm copper foil electrodes. An amplifier is designed to receive the MAET signal, and the gain of the amplifier is adjusted to be 54 dB. The phantom used in this paper is a mouse liver surrounded by a gel phantom with the conductivity of 0.7 S m-1. The gel phantom with the conductivity of 0.7 S m-1 is used to simulate the liver tumor, and the normal mouse liver is filled in the phantom. A series of the MAET signals are detected by the electrodes when the transducer is moved on a pre-set line route, then a B-scan image is realized. The experimental system can provide more information about the tumor and the results show that the MAET is sensitive enough for the potential clinical application of tumor in animal or human.


Assuntos
Acústica , Eletricidade , Fígado/diagnóstico por imagem , Campos Magnéticos , Tomografia/métodos , Algoritmos , Animais , Condutividade Elétrica , Eletrodos , Camundongos , Imagens de Fantasmas , Tomografia/instrumentação , Transdutores
8.
Opt Express ; 28(23): 34255-34265, 2020 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-33182899

RESUMO

A custom fibre laser designed as an excitation source for biomedical photoacoustic tomography has been developed. It is based on a custom-drawn large core diameter fibre (200 µm) that enables high pulse energies (∼10 mJ) to be achieved. The system can provide variable pulse durations (10 - 500 ns) and pulse repetition frequencies (100 Hz - 1 kHz), as well as arbitrary pulse bursts according to specific user defined sequences. The system is also compact and does not require external water cooling. This, along with the flexibility in the temporal characteristics of its output that it offers, will aid the translation of photoacoustic imaging to practical application in medicine and biology.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Dedos/irrigação sanguínea , Mãos/irrigação sanguínea , Imageamento Tridimensional/métodos , Técnicas Fotoacústicas/instrumentação , Tomografia/instrumentação , Desenho de Equipamento , Humanos
9.
Appl Opt ; 59(28): 8751-8758, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33104557

RESUMO

Biometric authentication is the recognition of human identity via unique anatomical features. The development of novel methods parallels widespread application by consumer devices, law enforcement, and access control. In particular, methods based on finger veins, as compared to face and fingerprints, obviate privacy concerns and degradation due to wear, age, and obscuration. However, they are two-dimensional (2D) and are fundamentally limited by conventional imaging and tissue-light scattering. In this work, for the first time, to the best of our knowledge, we demonstrate a method of three-dimensional (3D) finger vein biometric authentication based on photoacoustic tomography. Using a compact photoacoustic tomography setup and a novel recognition algorithm, the advantages of 3D are demonstrated via biometric authentication of index finger vessels with false acceptance, false rejection, and equal error rates <1.23%, <9.27%, and <0.13%, respectively, when comparing one finger, a false acceptance rateimprovement>10× when comparing multiple fingers, and <0.7% when rotating fingers ±30.


Assuntos
Identificação Biométrica/métodos , Dedos/irrigação sanguínea , Imageamento Tridimensional/métodos , Técnicas Fotoacústicas/instrumentação , Tomografia/instrumentação , Veias/anatomia & histologia , Humanos , Processamento de Imagem Assistida por Computador
10.
Rev Sci Instrum ; 91(9): 091501, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33003827

RESUMO

Magnetic induction tomography (MIT) is a non-invasive and non-contact imaging technology, which can be used in medical diagnosis by reconstructing the electrical distribution of biological tissues. Unlike other large medical imaging equipment, the device of MIT is with small size and low cost. The theoretical basis of MIT is by measuring the phase difference of magnetic flux density generated around the imaging objects, analyzing the eddy current distribution, and then using the reconstruction algorithms to obtain the electrical characteristic distribution of the object. This review introduces the development of imaging systems and the reconstruction algorithms of MIT as a medical assisted diagnostic technology, including the optimal design of the sensors, the excitation methods of the system, the calculation methods of the eddy current, and the improved methods of different reconstruction algorithms.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Fenômenos Magnéticos , Tomografia/instrumentação , Humanos
11.
IEEE Trans Biomed Circuits Syst ; 14(4): 775-786, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32746355

RESUMO

In this article, a novel method for measuring the volume of the urinary bladder non-invasively is presented that relies on the principles dictated by Electrical Impedance Tomography (EIT). The electronic prototype responsible for injecting innocuous electrical currents to the lower abdominal region and measuring the developed voltage levels is fully described, as well as the computational models for resolution of the so-called Forward and Inverse Problems in Imaging. The simultaneous multi-tone injection of current provided by a high performance Field Programmable Gate Array (FPGA), combined with impedance estimation by the Discrete Fourier Transform (DFT) constitutes a novelty in Urodynamics with potential to monitor continuously the intravesical volume of patients in a much faster and comfortable way than traditional transurethral catheterization methods. The resolution of the Inverse Problem is performed by the Gauss-Newton method with Laplacian regularization, allowing to obtain a sectional representation of the volume of urine encompassed by the bladder and surrounding body tissues. Experimentation has been carried out with synthetic phantoms and human subjects with results showing a good correlation between the levels of abdominal admittivity acquired by the EIT system and the volume of ingested water.


Assuntos
Impedância Elétrica , Análise de Fourier , Tomografia/instrumentação , Bexiga Urinária , Adulto , Eletrodos , Desenho de Equipamento , Humanos , Masculino , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador/instrumentação , Bexiga Urinária/anatomia & histologia , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/fisiologia
12.
IEEE Trans Biomed Circuits Syst ; 14(4): 787-799, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32406844

RESUMO

An ASIC for a high frequency electrical impedance tomography (EIT) imaging system for prostate cancer screening is presented. The ASIC enables a small form-factor architecture, which ensures high signal-to-noise ratio (SNR) at MHz frequencies. The 4-channel ASIC was designed and fabricated in a standard CMOS 0.18- µm technology and integrates a novel current driver for current stimulus, instrumentation amplifier to interface with the tissue, VGA to provide variable gain and ADC with SPI interface for digitization. A prototype miniaturized EIT system was built and it was evaluated using a model transrectal imaging probe immersed into a tank filled with saline and a metal inclusion that demonstrated the open-domain problem of imaging prostate cancer lesion. The system maintained an SNR between 66 and 76 dB over the frequency range of 500 Hz to 1 MHz. Also, it produced reconstructed EIT images that depicted the presence of the small metal inclusion that modeled a prostate cancer imaging application.


Assuntos
Impedância Elétrica , Miniaturização/instrumentação , Próstata/diagnóstico por imagem , Tomografia , Desenho de Equipamento , Humanos , Masculino , Imagens de Fantasmas , Neoplasias da Próstata/diagnóstico por imagem , Razão Sinal-Ruído , Tomografia/instrumentação , Tomografia/métodos
14.
Am J Ophthalmol ; 216: 90-98, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32277940

RESUMO

PURPOSE: We sought to assess the agreement of ray-traced corneal power values by 3 Scheimpflug tomographers tp construct the corresponding arithmetic adjustment factor in comparison with an automated keratometer (IOLMaster) and a conventional Placido-based topographer (Allegro Topolyzer). DESIGN: Prospective reliability analysis. METHODS: A total of 74 eyes from 74 healthy subjects who underwent corneal power measurements using Pentacam, Sirius, Galilei, IOLMaster, and Allegro Topolyzer were included. Ray-traced corneal power values, such as total corneal refractive power (TCRP), mean pupil power (MPP), total corneal power (TCP), mean keratometry (Km), and simulated keratometry (SimK) were recorded respectively and analyzed using one-way analysis of variance (ANOVA) and Bland-Altman plots. RESULTS: Among the 3 ray-traced corneal power values, TCRP and MPP did not differ significantly (P = 0.81), whereas TCP presented a slightly significant larger value (P < 0.001). Compared to Km or SimK, corneal power measurements by the ray tracing method exhibited significantly lower values (P < 0.001). Bland-Altman plots disclosed that the 3 Scheimpflug tomographers showed similar 95% limits of agreement after arithmetic adjustment compared with Km (-0.40 to 0.40 D, -0.39 to 0.39 D, and -0.35 to 0.34 D) or SimK (-0.50 to 0.51 D, -0.43 to 0.42 D, and -0.46 to 0.46 D). CONCLUSIONS: Ray-traced corneal power values obtained using 3 Scheimpflug tomographers with default diameter settings were similar, indicating that they could be used interchangeably in daily clinical practice. The 3 Scheimpflug tomographers were satisfactory in agreement after arithmetical adjustment compared with conventional automated keratometer or Placido-based topographer.


Assuntos
Córnea/fisiologia , Fotografação/instrumentação , Refração Ocular/fisiologia , Adulto , Córnea/diagnóstico por imagem , Topografia da Córnea/instrumentação , Feminino , Voluntários Saudáveis , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia/instrumentação , Adulto Jovem
15.
JAMA Ophthalmol ; 138(5): 519-526, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32215587

RESUMO

Importance: Evaluating corneal morphologic characteristics with corneal tomographic scans before refractive surgery is necessary to exclude patients with at-risk corneas and keratoconus. In previous studies, researchers performed screening with machine learning methods based on specific corneal parameters. To date, a deep learning algorithm has not been used in combination with corneal tomographic scans. Objective: To examine the use of a deep learning model in the screening of candidates for refractive surgery. Design, Setting, and Participants: A diagnostic, cross-sectional study was conducted at the Zhongshan Ophthalmic Center, Guangzhou, China, with examination dates extending from July 18, 2016, to March 29, 2019. The investigation was performed from July 2, 2018, to June 28, 2019. Participants included 1385 patients; 6465 corneal tomographic images were used to generate the artificial intelligence (AI) model. The Pentacam HR system was used for data collection. Interventions: The deidentified images were analyzed by ophthalmologists and the AI model. Main Outcomes and Measures: The performance of the AI classification system. Results: A classification system centered on the AI model Pentacam InceptionResNetV2 Screening System (PIRSS) was developed for screening potential candidates for refractive surgery. The model achieved an overall detection accuracy of 94.7% (95% CI, 93.3%-95.8%) on the validation data set. Moreover, on the independent test data set, the PIRSS model achieved an overall detection accuracy of 95% (95% CI, 88.8%-97.8%), which was comparable with that of senior ophthalmologists who are refractive surgeons (92.8%; 95% CI, 91.2%-94.4%) (P = .72). In distinguishing corneas with contraindications for refractive surgery, the PIRSS model performed better than the classifiers (95% vs 81%; P < .001) in the Pentacam HR system on an Asian patient database. Conclusions and Relevance: PIRSS appears to be useful in classifying images to provide corneal information and preliminarily identify at-risk corneas. PIRSS may provide guidance to refractive surgeons in screening candidates for refractive surgery as well as for generalized clinical application for Asian patients, but its use needs to be confirmed in other populations.


Assuntos
Topografia da Córnea/métodos , Aprendizado Profundo , Ceratocone/diagnóstico , Procedimentos Cirúrgicos Refrativos , Tomografia/instrumentação , Adulto , Algoritmos , Inteligência Artificial , China , Estudos Transversais , Feminino , Humanos , Ceratocone/classificação , Ceratocone/cirurgia , Aprendizado de Máquina , Masculino , Modelos Teóricos , Curva ROC , Adulto Jovem
17.
Physiol Meas ; 41(4): 044002, 2020 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-32160596

RESUMO

OBJECTIVE: The aim of the study was to examine whether an electrical impedance tomography (EIT) electrode belt changed the lung function in healthy volunteers and patients with respiratory muscle weakness (RMW) and chronic obstructive pulmonary disease (COPD). APPROACH: In total, thirty subjects were included (10 healthy volunteers, 10 subjects with RMW, maximum inspiratory pressure < 40 cmH2O, and 10 COPD, grade I-IV). Spirometry measurements were conducted in a sitting position once a day at similar times on two consecutive days. Slow expiratory vital capacity (VC), forced vital capacity (FVC) and maximum voluntary ventilation (MVV) manoeuvres were performed. On day 1, spirometry was performed without the EIT electrode belt, and on day 2, the belt was attached to the thorax. MAIN RESULTS: Lung function was not influenced by the electrode belt in healthy subjects. The test-retest reliability in the healthy group was 0.89, 0.89 and 0.85 for VC, FVC and MVV, respectively. On the other hand, all investigated parameters were significantly decreased in the RMW group (VC, 51.3 ± 18.0 versus 46.5 ± 18.0% predicted, without versus with EIT belt, p< 0.01; FVC, 51.7 ± 19.0 versus 45.8 ± 18.1% predicted, p< 0.01; MVV, 41.0 ± 20.0 versus 38.8 ± 19.6% predicted, p< 0.01). VC and MVV also decreased significantly in the COPD group (VC, 77.4 ± 20.5 versus 74.6 ± 18.8% predicted, p< 0.05; MVV, 57.4 ± 15.7 versus 54.4 ± 12.5% predicted, p< 0.05). SIGNIFICANCE: An EIT electrode belt could reduce lung volumes in subjects with pre-existing lung diseases. Comparing lung function acquired with an electrode belt to corresponding values obtained without the belt should be avoided.


Assuntos
Testes de Função Respiratória , Postura Sentada , Espirometria , Tomografia/instrumentação , Artefatos , Estudos de Casos e Controles , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Debilidade Muscular/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia
19.
J Cataract Refract Surg ; 46(4): 581-590, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32050208

RESUMO

PURPOSE: To evaluate the precision of elevation and wavefront aberration measurements with the Pentacam HR (Oculus Optikgeräte GmbH). SETTING: Flinders University, Australia. DESIGN: Instrument evaluation study. METHODS: A randomly selected eye of 100 participants was scanned twice with the Pentacam HR by 1 observer on the 3 measurement modes: 25-picture, 50-picture, and cornea fine. A second observer performed 2 scans on the same random eye with the 25-picture mode. Repeatability and reproducibility were assessed using the within-subject SD (Sw) statistic from a 1-way analysis of variance. RESULTS: From the 100 scanned eyes, the higher-order aberration root mean square (RMS) repeatability limit for both elevation and wavefront, and anterior and posterior measurements was 0.03 µm for all 3 measurement modes. Anterior, posterior, and total corneal wavefront Zernike terms were highly precise, with most Zernike terms displaying a repeatability limit of 0.03 µm. The least repeatable measurement was the posterior elevation Zernike term with the 25-picture scan (repeatability limit 1.50 µm). The cornea fine measurement mode provided the most precise measurements. Reproducibility limits (second observer) were similar to repeatability limits with the 25-picture scan mode. CONCLUSIONS: The Pentacam HR provided highly precise aberration outputs. The most precise measurements are achievable with the cornea fine measurement mode and wavefront aberrations. One should be cognizant of posterior elevation aberration precision, particularly for lower radial order and higher azimuthal frequency terms. Accounting for tilt and misalignment of aberrations, all RMS and Zernike aberrations were extremely precise (repeatability and reproducibility limit less than 0.000001 µm).


Assuntos
Córnea/diagnóstico por imagem , Aberrações de Frente de Onda da Córnea/diagnóstico por imagem , Fotografação/métodos , Tomografia/instrumentação , Adulto , Idoso , Córnea/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Refração Ocular/fisiologia , Reprodutibilidade dos Testes , Acuidade Visual/fisiologia , Adulto Jovem
20.
Physiol Meas ; 41(3): 035002, 2020 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-32000152

RESUMO

OBJECTIVE: Electrode detachment may occur during dynamic brain electrical impedance tomography (EIT) measurements. After the faulty electrodes have been reset, EIT can restore to steady monitoring but the corrupted data, which will challenge interpretation of the results, are notoriously difficult to recover. APPROACH: Here, a piecewise processing method (PPM) is introduced to manage the erroneous EIT data after reattachment of faulty electrodes. In the PPM, we define the three phases before, during and after reconnection of the faulty electrode as PI, PII and PIII, respectively. Using this definition, an empirical mode decomposition-based interpolation method is introduced to compensate the corrupted data in PII, using the valid measurements in PI and PIII. Then, the compensated data in PII are spliced at the end of PI. Thus, there will be a surge at the junction of PII and PIII due to the changes in contact state of the repositioned electrodes. Finally, to ensure all the EIT data are obtained under constant electrode settings, we calculate the above changes and eliminate them from the data after PII. To verify the performance of the PPM, experiments based on head models, with anatomical structures and with human subjects were conducted. Metrics including permutation entropy (PE) and image correlation (IC) were proposed to measure the stability of the signal and the quality of the reconstructed EIT images, respectively. MAIN RESULTS: The results demonstrated that the PE of the processed data was reduced to 0.25 and the IC improved to 0.78. SIGNIFICANCE: Without iterative calculations the PPM could efficiently manage the erroneous EIT data after reattachment of the faulty electrodes.


Assuntos
Encéfalo/diagnóstico por imagem , Erros Médicos , Tomografia/instrumentação , Impedância Elétrica , Eletrodos , Entropia , Análise de Elementos Finitos , Humanos , Processamento de Imagem Assistida por Computador